Abstract

The purpose of the work was to study prognostic factors for the effectiveness of extracorporeal shock wave lithotripsy in patients with ureterolithiasis. Materials and methods. The study included 53 patients with ureteral stones up to 2 cm in size. All patients underwent extracorporeal shock wave lithotripsy under ultrasound control, with a pulse rate of 90 per minute and a maximum number of pulses of 2000 per session. The outcome of treatment was evaluated by ultrasound on day 5 after the extracorporeal shock wave lithotripsy session. If there were stone fragments larger than 5 mm, a second extracorporeal shock wave lithotripsy session was performed. Treatment was considered effective in the absence of stone fragments in the urinary tract 4 weeks after extracorporeal shock wave lithotripsy. Results and discussion. The data were analyzed to identify clinical and radiological factors associated with treatment failure. As a result of the treatment, 46 (86.4%) patients were found to have no stones in the urinary tract (the condition is “stone free”), 9 (13.6%) had stone fragments larger than 5 mm 4 weeks after extracorporeal shock wave lithotripsy, and therefore contact ureterolithotripsy was performed. As complications, 7 (13.2%) patients had an exacerbation of chronic pyelonephritis, which required percutaneous nephrostomy. As the results showed, age, gender, body mass index, and Hausfield units did not differ significantly in terms of extracorporeal shock wave lithotripsy results. Factors that significantly affected the prognosis of extracorporeal shock wave lithotripsy success were the size of the stone and skin-stone distance. Body mass index did not significantly affect the outcome of lithotripsy in this study. The stone density index according to computed tomography data is considered by many authors to be a predictor of the effectiveness of fragmentation, but in our study this indicator was not a significant predictor of the effectiveness of extracorporeal shock wave lithotripsy, which allows us to think that there are other factors, namely the features of the internal structure of the stone, which determine its compliance with the shock wave. Conclusion. The size of the stone and the skin-stone distance are prognostic factors that affect the effectiveness of extracorporeal shock wave lithotripsy in patients with ureterolithiasis. Body mass index and stone density in Hausfield units did not significantly affect extracorporeal shock wave lithotripsy outcome in this study

Highlights

  • У дослідження були включені 55 пацієнтів з каменями сечоводу розміром до 2 см

  • radiological factors associated with treatment failure

  • patients were found to have no stones in the urinary tract

Read more

Summary

Introduction

При наявності фрагментів каменю більше 5мм проводили повторний сеанс екстракорпоральної ударно-хвильової літотрипсії. Лікування вважалось ефективним в разі відсутності фрагментів каменю в сечовивідних шляхах через 4 тижні після екстракорпоральної ударно-хвильової літотрипсії. У 9 (16,4%) на 4 тижні після проведеної екстракорпоральної ударно-хвильової літотрипсії відмічалися фрагменти каменю більше 5мм, у звязку з чим було виконано контактну уретеролітотрипсію. Показник щільності каменю за даними комп’ютерної томографії багатьма авторами вважається предиктором ефективності фрагментації, однак у нашому дослідженні даний показник не був значущим предиктором ефективності екстракорпоральної ударно-хвильової літотрипсії, що дозволяє вважати, що існують інші фактори, а саме особливості внутрішньої структури каменю, які зумовлюють його піддатливість дії ударної хвилі. Розмір каменю та відстань від латеральної поверхні каменю до шкіри є прогностичними факторами, які впливають на ефективність екстракорпоральної ударно-хвильової літотрипсії у пацієнтів з уретеролітіазом. У дослідження були включені 54 пацієнти з каменями сечоводу яким було проведено ЕУХЛ на базі КНПХОР «Обласний медичний клінічний центр урології і нефрології ім. Камені діагностувалися на підставі проведення комп’ютерної томографії на мультиспіральному комп’ютерному томографі Toshiba Aquilion 16 (Японія)

Objectives
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call