A GM-type two-stage pulse tube refrigerator equipped with three rotary valves was developed, and the lowest temperature of 10.3K was obtained when lead shots were used as the second-stage regenerator material. From the measured pressure oscillation at both sides of the orifice plate connected to the pulse tube hot ends, the mass flow rate through the orifice was estimated and the equivalent PV work calculated. Based on the cooling capacity and calculated PV work, the refrigeration losses were found to depend on the temperature difference of the regenerator and showed a linear relation for both stages.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.