Abstract

A stand-alone data logger was developed for biological exposure experiment in space. A combibnation of one chip micro computer with electrically erasable programabble read only memory, real timer counter and analog awitch enables measurement of temperature every 10 minutes (default) for a period of one year at electric power supplied from lithium primary battery. It can be operated under thermal swing between - 80 and +80 degree C, expected during expoosure on outer environemnt of the International Space Station or biological orbiting satellites. Physical size and mass of the prototype logger are 46 x 35 x 14 mm and 24g (not including potting material coated over the circuit board nor a pressurized container for the logger).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.