Abstract

An experimental work has been carried out to explain the Diesel spray behavior. The measurement is per-formed for the spray tip penetration and the spray angle with three different injection pressures and ambient gas density. The change of ambient gas density has been done with pressured N2 gas and a high density SF6 gas. The density of SF6 gas is about 5.3 times N2 gas at room conditions. The obtained results for spray tip penetration are simplified with non-dimensional form. The form is based on Break-up length and time. As a result, the non-dimensional data with N2 gas fit to a curve that is unaffected with different injection pressure and ambient gas density. Moreovere, the measurement result (penetration and angle) with SF6 gas has been shown same result with N2 gas. Therefore, the potential of the non-dimensional expression method for the spray tip penetration is confirmed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.