Abstract

Some kinds of the electrical cables and elastomer/plastomer materials, though having high outgassing rates, are occasionally used in a high vacuum system. In order to evaluate the ultimate pressure of the system in which those materials are to be installed, their outgassing rates have been measured as a function of pumping time by a through-put method. The outgassing rates of the cables and glass-fiber sleevings ranged from 10-9 to 10-5 Pa·m3. s-1. m-1 at 100 h, depending on the insulation materials or varnishing treatment. From the tests of the elastomer/plastomer materials, it was ascertained that the organic materials give high outgassing rates of the orders of 10-5 to 10-3 Pa·m3·s-1·m-2 at 100 h.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.