Abstract

In this paper, we studied electrical characteristics of internal converter type of LED lamps for road and street lighting. We surveyed electro-technical regulations and KS(Korean industrial standards) about LED luminairs. Waveforms of voltage and current, thermal distributions, insulation resistances between live parts and exposed conductive parts, and flame test of cover of LED lamps were experimented and analyzed. In regulations, insulation resistance between live conductors and exposed conductive parts should be greater than 0.2㏁ in case nominal voltage of wiring is 220V. In KS codes, the value of insulation resistance should be greater than 2㏁ while applying DC 500V or DC 100V. In the result of this study, waveforms of primary voltage and current were distorted. There was difference in waveforms of secondary voltage and current according to composition of converter. Mostly, insulation resistances were measured high more than regulation and code value but some measured points were measured badly(0.0㏁). Cover of LED lamps was ignited easily. We expect that the results of this study would be helpful for revision of regulations and national codes for the electrical safety of LED road and street lighting.