Abstract

A computer code, FANTOME-90, was developed to calculate the equivalent doses in organs or tissues and the effective dose as well as the effective dose equivalent by the Monte Carlo method for external photon irradiation. The code treats a mathematical human phantom with movable arms and legs, which has been derived from the MIRD-5 phantom. The code enables to make the phantom take any posture by specifying the angles of each part of its arms and legs and wear individual monitors on its surface. The MORSE-CG code is incorporated in the FANTOME-90 code to calculate the photon transport from a source to the organs or tissues. The effective dose equivalent was calculated for this phantom in a standing posture and compared to that calculated for the MIRD-5 phantom. A good agreement obtained between them shows that the modification of the original MIRD-5 phantom gives no significant effect to the dose calculation. The values of effective dose calculated in different postures are given as an example.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.