Special-purpose turbine—generator units (TGUs) with a capacity of up to 10 000 kWfor converting the mechanical energy of steam into electricity with improved vibroacoustic characteristics are studied. The TGU includes a steam turbine, a synchronous generator excited from permanent magnets, and a frequency converter regulating the parameters of the electric power output. The turbine and generator rotation frequency is such that the TGU output frequency varies from 50 to 300 Hz depending on the TGU power. Different basic circuits of self-contained units equipped with generators excited from permanent magnets are considered. The design of a turbine—generator unit equipped with parallel-connected frequency converter is proposed, the use of which makes it possible to achieve essentially better mass and dimension characteristics of the converter and enhance the TGU reliability as a whole.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.