Abstract

The purpose of this study is to improve an EDMed surface by application of gas-nitriding process. Evaluation of the effect was made by using thermal fatigue apparatus. Cracks prevented from growing by the nitride layer formed by the process. Total cracks seen on the section of the die steel were considerably fewer in number than EDMed one after a thermal fatigue test. It is suggested that the treatment to EDMed surfaces improves the life of die steels. Furthermore, a nitrided layer was decomposed by the thermal fatigue test and turned into a diffusion one that reduce the growth of the cracks.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.