Abstract
The article is written about studying of radiation safety of 188Re-labeled microspheres of albumin preparation (hand mode) for treatment of resistant synovitis. The study material was a radiopharmaceutical based on albumin microspheres 5 –10 µm with rhenium-188 for treatment of resistant synovitis. The studying has led to conclusion the number of radiopharmaceutical portions prepared by one operator should not exceed 70 times a year, which will ensure that the main limits of equivalent doses to hands and skin with a reserve factor of 2 (250 μSv/h) are not exceeded. Protective equipment should be used to reduce doses to hands, as the most critical to operator's body part irradiation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.