The article is written about studying of radiation safety of 188Re-labeled microspheres of albumin preparation (hand mode) for treatment of resistant synovitis. The study material was a radiopharmaceutical based on albumin microspheres 5 –10 µm with rhenium-188 for treatment of resistant synovitis. The studying has led to conclusion the number of radiopharmaceutical portions prepared by one operator should not exceed 70 times a year, which will ensure that the main limits of equivalent doses to hands and skin with a reserve factor of 2 (250 μSv/h) are not exceeded. Protective equipment should be used to reduce doses to hands, as the most critical to operator's body part irradiation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.