Abstract

A bioequivalence study of tablets (Dong Wha Pharm. Ind. Co., Ltd.) to tablets (Boehringer Ingelheim Korea, Ltd.) was conducted according to the guideline of Korea Food and Drug Administration (KFDA). Twenty four healthy male Korea volunteers received each medicine at the ambroxol hydrochloride dose of 30 mg in a crossover study. There was a one-week wash out period between the doses. Plasma concentrations of ambroxol were monitored by a high-performance liquid chromatography for over a period of 24 hours after the administration. (the area under the plasma concentration-time curve from time zero to 24 hr) was calulated by the linear trapezoidal rule method. (maximum plasma drug concentration) and were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed . No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the ratio and the ratio for were 0.89-1.01 and 0.89-1.02, respectively. These values were within the acceptable bioequivalence intervals of 0.80-1.25. Thus, our study demonstrated the bioequivalence of with respect to the rate and extent of absorption.