Abstract

This paper presents the results of survey on 276 grid-connected PV generation systems and measurement of 7 systems in Kyushu area. The electricity generated for a year was in average 925.9kWh/kWp/year. It was found that the system with panels on one side of roof generates more electricity than the system with panels on plural side of roof. The electricity generated by the system with panels on one side of roof was approximately 10% more than that with panels on three sides of roofs. The amount of electricity generation from PV system is in general affected by the local solar radiation condition and the system efficiency. The relation between decrease in power generation and the shadow on the panel or the unbalanced solar radiation between panels was simulated using the data acquired by the experiment.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.