The construction of a solar dryer-grain storage facilities is described. The design of a auger conveyor-distributor of grain for its loading is offered. The dependence of the width of the discharge opening in the casing of the auger conveyor-distributor on its length is obtained. The results of laboratory tests of the auger conveyor-distributor of grain are presented. It is established that the minimum initial width of the drain opening for wheat grain should be not less than 9 mm. The conditions of uniform distribution of grain by the auger conveyor-distributor are justified: the filling factor of the auger interturn space in its loading zone – 0.35; the length of the discharge opening of the charging hopper should be equal to the doubled value of the auger pitch size. In this case, the uneven distribution of grain along the discharge opening will be no more than 5%.