Abstract

The accuracy of the location of acoustic emission (AE) sources in the concentrator zones (central holes 5 mm in diameter) located at a distance of 40 mm from the receiving transducers during tensile tests of steel, aluminum alloy and composite flat specimens with dimensions of 550x50x4 mm was evaluated. Calculated speed dependence of propagation of pulses on the level of their amplitude and the partial energy of the high-frequency components of the spectrum is studied. With the threshold method of signal registration, the error in the location of AE event sources arising in the near zone of the receiving transducers at a distance 𝛥L<0.1 m can significantly exceed 10% relative to the base size (B) of the location area, when B<0.5 m. Moreover, with a decrease in the distance 𝛥L<0.05 m, the level of possible error will increase, reaching 20-30% relative to the basic size of the antenna array, when recording pulses with an amplitude level um<60 dB and a fraction of the energy of high-frequency spectrum components not exceeding 10%.