Abstract

Occlusal force distribution is considered to be one of the major factors for bone resorption underneath denture base. We developed the program for simulating this process utilizing a two dimensional finite element model and an optimization program. In this report, influence of rigidity of denture base, loading condition, rebase and reline and on bone resorption were examined and following results were obtained.1. Rigidity of the denture structure had much influence on bone resorption. Denture base with high rigidity caused less resorption compared to the one with low rigidity.2. Area and amount of bone resorption were closely related to the loading location and direction. Least amount of resorption was found when the load applied vertically at the palatal side.3. Rebase and reline procedure without altering occlusion could result in further resorption.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.