The purpose of this study is to predict the critical speed of an axial fan using finite element analysis. The critical speed has an important meaning in evaluating the stability against the occurrence of overload of the ventilation system in an emergency situation of the axial fan. Through finite element analysis, the maximum stress acting on the axial fan was derived, and the results were derived for permanent deformation and fracture of the material by dividing it into an elastic region and a plastic region. The critical speed of the axial fan through the overspeed test and the analysis results of the finite element analysis were compared.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.