Abstract

Turbo blowers are mainly used in refuse collection systems. We discuss blower performance in relation to the angle of the inlet vane installed at the upstream of the blower. The flow characteristics of the components are analyzed by three-dimensional Navier-Stokes analysis and compared to experimental results. A two-stage serially connected turbo blower is introduced to analyze the performance experimentally. Throughout the experimental measurements and the numerical simulation, the distorted inlet velocity generated in the small vane angle reduces the performance of the blower, because of the local leading-edge separation and the resulting non-uniform blade loading. We also perform a detailed flow analysis using the results obtained in the numerical simulation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call