Abstract

The Emergency Diesel Generator (EDG) is a very important equipment for the safety of a Nuclear Power Plant (NPP). In this study, the operating vibration of three kinds of EDG systems was measured. The target EDG systems are Yonggwang 5 unit and Ulchin 2 and 3 units. The Yonggwang 5 and Ulchin 3 unit EDG systems are the same type but the foundation systems are different. One is an anchor bolt type and the other is a spring and viscous-damper type. The purpose of these measurements is for a verification of the vibration isolation effect depending on the foundation system. As a result, It can be said that the spring and viscous damper system of the EDG performed better for the vibration isolation than that of anchor bolt type.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call