Abstract

This paper presents dynamic characteristics of pneumatic artificial muscles. Since the actuating performance of a pneumatic muscle is closely related to the input pressure of a pneumatic muscle, the air flow model on a valve orifice and an elastic bladder of the muscle is formulated to estimate precisely the pressure variance of pneumatic muscles during deflating and inflating process. Frequency response experiments are performed with an antagonistic system consisting of two pneumatic muscles and fast pneumatic control valves. Comparing with experimental results, the proposed model yielded good performance in estimating dynamic motions of the antagonistic system as well as the pressure variance of the pneumatic artificial muscles

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.