Abstract

The popularity of diesel engines is derived primarily from their higher thermal efficiency resulting from higher compression ratio. NOx removal from the diesel emissions is very important to meet stringent emission regulations. NOx emission from diesel engines is removed by an urea-SCR or an LNT system. The urea-SCR system needs the urea-solution supply system with concentration and level sensor. This study was carried out to develop a sensor for the measurement of urea-solution concentration by an electric conductivity method. Considering experimental parameters were the material of electrode, two kinds of electric power(AC or DC), the distance between two electrodes, and the length of electrode. It was found that the AC electric power was more useful to measure the urea-solution concentration compared to DC, because it prevented an ionization of the urea-solution. The silver rod coated with Pt is the most useful electrode, tendency of which is similar to Pt rod, and the cost is more economic. We could also find out the optimum distance between two electrodes and the length of electrode was 10mm and 3mm, respectively.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call