Abstract

To detect faults and monitor thinning on a pipe, many people use ultra sonic sensors that are operated in high frequency range. Because there are many modes in high frequency range, it is difficult to find faults and monitor pipe thinning on a structure. If we deal with signals in a low frequency range which include only A0 wave and S0 wave, the information of monitoring and diagnosis can be easily obtained. In this paper, the technique for exciting low frequency range using ultra sonic sensors is proposed. The main idea of the proposed method comes from the beat phenomenon. The beat frequency is equal to the absolute value of the difference in frequency of the two waves. If the beat frequency is tuned by two ultra waves, we can excite A0 mode and S0 mode of structures. To verify the proposed method, we have performed a steel plate and pipe experiments. Experimental results show that two ultra sonic sensors can well excite low frequency range.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call