Abstract

In this study, control of oxidizer mass flow rate and verification of control system were performed for hybrid rocket thrust control application. Oxidizer flow control system consists of ball valve and stepping motor where gaseous oxygen was used for oxidizer at feeding pressure of 10, 20 and 30 bar. According to experimental results, the oxidizer mass flow rate showed a relatively linear increment as ball valve open angle increases regardless of feeding pressure. In addition, the level of the oxidizer flow rate was kept almost constant at each sequence of flow control with ball valve during the 20 seconds of operation.