Abstract

The helium engineering demonstration loop (HENDEL) consists of the first and second helium loops (M1 and M2 loops), adapter helium loop (A loop) and six test sections, the first of which was completed and the others to be designed.This report describes operational data of components (heater, blower and cooler) and overall performance of the second helium loop (M2 loop) and adapter helium loop (A loop), during the test operation until March 1983.Finally M2 and A loops were confirmed to be able to provide helium gas up to 1, 000°C, 4.0kg/s and 4.0MPa to the in-core structure test section (T2) and the others which are to be installed.