Abstract
Elastic-plastic fracture mechanics is popularly used for integrity evaluation of major components, however, it is not easy to extract standard specimens from operating facility. This paper examines how ductile fracture toughness is characterized by a small punch testing technique in conjunction with finite element analyses incorporating a damage model. At first, micro-mechanical parameters constituting Rousselier model are calibrated for typical nuclear materials using both estimated and experimental load-displacement (P-?) curves of miniaturized specimens. Then, fracture resistance (J-R) curves of relatively larger standard CT specimens are predicted by finite element analyses employing the calibrated parameters and compared with corresponding experimental ones. It was proven that estimated results by the proposed method using small punch specimen is promising and might be used as a useful tool for ductile crack growth evaluation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Transactions of the Korean Society of Mechanical Engineers A
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.