The ventilation performance of a Velo-typed greenhouse at high temperature atmosphere condition is investigated by means of computational simulations using a commercial software. The solar radiation is simulated using the Discrete Ordinates model, and the conduction through the covering material of the greenhouse and soil are calculated. The numerical scheme is validated by comparing the experimental result for the Almeria greenhouse. The natural ventilation performance through windows of the Velo-typed greenhouse is evaluated at free-stream velocity 0 m/s and 2.5 m/s. It is shown that the natural ventilation caused by the temperature difference is more efficient through windows on the ceiling than those on the sides.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.