Most upland in Korea have irregular field shapes. Boom sprayers working alone winding row will show considerable differences of spraying amount per unit area between left and right booms. If flow rates of both booms are equal. This phenomenon becomes significant as steering radius of sprayer decreases. This study was performed to seek a method which reduce the difference of the spray amount between left, right and center booms while spraying along curvy rows. A flow rate control method for keeping application rate of each boom section constant was proposed and experimentally proved using a boom sprayer attached to a cultivating tractor. The flow rate control device was composed of 3 ball valves and a rotary angle sensor. The rotary angle sensor showed a symmetric voltage output with respect to steering radius. The spray overlapping was happened in a boom nearby the steering center when steering radius of the sprayer was less than 5.2 m. Flow rates for left, right and center booms were regulated using ball valves based on the steering radius and spraying areas ration of right/left boom. The Maximum spraying area ratio () of left to right boom section was 1:3.6 at the steering radius of 5.2 m. However, The Maximum achieved right and left spraying flow ratio was 1:2.7.