Abstract

This paper proposes the development of a new method for online analysis which measured acid concentration in a pickling line. Pickling is the most important step to remove surface scale layers and is strongly depending on the exactly controlled pickling liquor composition. Today, there is no feasible system available for the online control of pickling lines. Within this paper, new methods for online analysis of pickling liquors have been tested and implemented into an overall pickling process control tool. This method measured simultaneously the hydrochloric acid and iron ion concentration in a solution of hydrochloric acid by measuring the ultrasonic speed, the solution temperature, and the electrical conductivity. Experimental results showed excellent precision and the measurement error was <TEX>${\pm}2g/l$</TEX> compared with the neutralization titration measurement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.