Abstract

The linear polarization resistance method is one of the widely used techniques for the corrosion rate monitoring in the water circulating systems of plants. The measurement is simple and rapid, so that a continuous on-line monitoring is possible without any shutdown of plants. A 2-electrode Polarization corrosion rate measurement system was installed in a laboratory using a data acquisition board and PC. The signal processing parameters were optimized for the accurate corrosion rate measurement, and the polarization resistance was compensated with the solution resistance measured by the high frequency sine wave signal of an output channel. The precision of corrosion rate data was greatly improved by removing the initial noisesignals on measuring the polarization resistance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.