Abstract

The droplet ejection behavior from drop-on-demand printhead are investigated numerically in terms of the non-dimensional parameters. The numerical simulation is performed using a volume-of-fluid model. It is important to eject droplet within the printability range, where the droplet is ejected in stable manner without satellite droplets. Generally, the printability range has been determined by Z number, which is the inverse of Oh number. However, it is found that the ejection of droplets with same Z number can exhibit different behavior depending on the value of Ca and We number. Therefore, it is insufficient to determine the printability range only with Z number. Instead, other non-dimensional parameters, such as Ca and We number, should be considered comprehensively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.