Abstract
The fault detection technique of the grid-connected photovoltaic system using wavelet transform has been suggested in this paper. The additional hardware and sensors are required to detect the inverter failure in the conventional method, and it has the disadvantage of high cost and re-design problem if the inverter specification has been changed. The suggested method used the inverter voltage and current waveform to detect the failure and the location by the wavelet coefficients variations. The prompt and accurate diagnostic function is possible using the normalized standard deviation method. The merit of the proposed method is the simple calculation and precise diagnostic capabilities of the fault detection. The computer simulation is performed and the experimental result verifies the validity of the proposed method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Transactions of the Korean Institute of Power Electronics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.