Abstract

Purpose of the study: based on the analysis of the bispectral index (BIS-index), to assess the adequacy of the depth of anesthesia in patients with oncological profile. Material and methods. An analysis of BIS-monitoring was carried out during 77 surgical interventions in patients of the oncosurgical profile of the Grodno University Clinic. Results. 30 minutes after the start of surgery, a decrease in the concentration of Sevorane in the inhaled mixture to 0.8-0.6 vol% lead to a significant decrease in the minimum alveolar concentration (MAC) of the anesthetic. However, at the same time, the BIS-index during the operation did not go beyond the limits of acceptable values. There was a decrease in the BIS-index (p<0.05) only during induction anesthesia and during the formation of anesthesia in the first minutes of surgery (57.87 and 47.65 units). Conclusions. With a decrease in the concentration of inhalation anesthetic in the inhaled air to 0.8-0.6 vol% and, consequently, MAC to 0.6-0.7, no statistically significant differences were found in the increase in the BIS-index and in the decrease in the depth of anesthesia.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.