This study was conducted to examine the effect of different types of milking instrument and season on milk composition (fat, protein, non-fat milk solids, milk urea nitrogen and somatic cell count) on Holstein-Friesian lactating cows. Raw milk samples were collected from 20 automatic milking system (AMS) installed dairy farms and 85 conventional milking system (CMS) installed dairy farms. Milk fat, protein, NFMS and MUN contents did not changed between AMS and CMS and different seasons. On the other hand, the average SCC in AMS was <TEX>$239{\times}10^3cells/mL$</TEX> which was lower than in CMS (<TEX>$373{\times}10^3cells/mL$</TEX>, (p<0.05). In conclusion, present results indicated that SCC in milk might be influenced by AMS. However, this area needed more study to confirm the reason of reducing SCC content from AMS.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.