Abstract

This paper proposes an alternating battery discharge method by balancing discharge time of battery cells, which significantly increases battery lifetime. In the conventional method, several battery cells are alternately discharged to make battery recovery effect, and this increases battery lifetime. In this case, there are some overlap intervals where several battery cells are ON to avoid system power cut-off, but this makes several problems due to the voltage differences of battery cells. To mitigate these problems, discharge time of battery cells are controlled to make battery cell voltages as equal as possible. Measurements show that the battery lifetime is exxtended by 19.2% in the proposed method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.