Comparative results of capacity renewal of sealed nickel-cadmium batteries with asymmetric and direct currents after their long-term storage are represented. Capacity renewal with asymmetric current was carried out in an accelerated manner at average value of the charging current equal to 0,25Crated. Capacity renewal with direct current was carried out at average value of the charging current equal to 0,1Crated in accordance with Technical Conditions. Applying asymmetric current for battery capacity renewal allowed to half in comparison with applying direct current for this purpose – the number of necessary renewal cycles before accumulators would gain rated capacity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.