Abstract

Dual frequency acoustic pinger(AP) was manufactured to reduce study effect by long-term use of developed single frequency AP to prevent cetacean bycatch. Directivity characteristic of transducer was the omnidirectional pattern which showed less than the change range of sensitivity on the beam pattern of right and left. Source power level(SPL) was 1384311pa with epoxy window before casing however after casing 1170B11Pa at sea. Dual frequency Af was tested to identify the avoidance behavior of bottlenose dolphin by its working. However the efficiency of dual frequency AP about the study effect was verified experiment repeatedly using single and dual frequency AP.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call