Abstract

In this study, we developed an M-COS (molit coagulant-dosing optimization system), which enables to apply the optimum coagulant dose determined in real time, in order to satisfy the total phosphorus (TP) regulation (0.5 mg/L), and then tested its field applicability. Field tests were conducted at three different periods in 2014 in a pilot plant where the M-COS was installed. Coagulant reduction rate by the M-COS was 10.4%, 15.3%, and 9.0% for each period (average 11.6%), when comparing with a control where coagulants were applied at a constant rate. Total cost for the M-COS or control was estimated by summing up the coagulant cost and sludge treatment cost, and then the resulting cost increase was predicted. Cost reduction rate by the M-COS was 13.8%, 20.0%, and 11.4% for each period (average 15.0%). This study indicates that the M-COS can be an alternative to a conventional system for TP treatment, with a better cost efficiency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.