Abstract

In seawater reverse osmosis desalination plant, pumps consume nearly 90% of the electrical energy. The purpose of this study is to compare the energy consumptions of the high pressure pump before the installation of inverter and after the installation of the inverter and to evaluate the performance of variable speed driven high pressure pump. Calculated energy saving of the variable speed driven high pressure pump was around 14% at relatively clean condition of the membrane. However, the certain extent of the saving should be continuously monitored year by year depending on the fouling and aging of the membranes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.