Abstract
In this paper, we compare and analyze the characteristics of the boosting current ratio, which occurs differently depending on the ground configuration of the traction line, to derive the main causes of the fault location error. To this end, the Power system analysis program (PSCAD/EMTDC) is utilized to derive the characteristics of the boosting current ratio due to the other-line absorption phenomenon through modeling and simulation. Furthermore, to derive problems from existing calibration methods, we analyze facial expression errors by classifying single linear interpolation calibrations into multiple cases. We present a correction technique using linear spline interpolation to improve the accuracy of the fault point representation even under the nonlinear boost current ratio characteristic conditions due to integrated ground and other line absorption phenomena.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The transactions of The Korean Institute of Electrical Engineers
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.