Abstract

An experimental study was conducted to investigate the water temperature distribution and saturated boiling phenomenon in a small-scale passive condensate cooling tank that is part of an emergency passive auxiliary feedwater system used in nuclear power plants. During the heating process using an electric heater inserted in the tank, the temperature of water was measured at 36 locations. Isothermal line contours were generated based on the experimental data. The contours indicated that the water above the heater location had a nearly uniform temperature due to free convection flow. Conversely, a strong temperature gradient was observed in the water below the heater location. The bubble departure diameters at the cylindrical heater surface were measured using images captured by a high-speed camera. The diameters were observed to be within the range of values predicted using existing correlations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.