Abstract

Rapid on-site sensing of nitrate-nitrogen and potassium ions in hydroponic solution would increase the efficiency of nutrient use for greenhouse crops cultivated in closed hydroponic systems while reducing the potential for environmental pollution in water and soil. Ion-selective electrodes (ISEs) are a promising approach because of their small size, rapid response, and the ability to directly measure the analyte. The capabilities of the ISEs for sensing nitrate and potassium in hydroponic solution can be affected by the presence of other ions such as calcium, magnesium, sulfate, sodium, and chloride in the solution itself. This study was conducted to investigate the applicability of two ISEs consisting of TDDA-NPOE and valinomycin-DOS PVC membranes for quantitative determinations of <TEX>$NO_3$</TEX>-N and K in hydroponic solution. Nine hydroponic solutions were prepared by diluting highly concentrated paprika hydroponic solution to provide a concentration range of 3 to 400 mg/L for <TEX>$NO_3$</TEX>-N and K. Two of the calibration curves relating membrane response and nutrient concentration provided coefficients of determination (<TEX>$R^2$</TEX>) > 0.98 and standard errors of calibration (SEC) of < 3.79 mV. The use of the direct potentiometry method, in conjunction with an one-point EMF compensation technique, was feasible for measuring <TEX>$NO_3$</TEX>-N and K in paprika hydroponic solution due to almost 1:1 relationships and high coefficients of determination (<TEX>$R^2$</TEX> > 0.97) between the levels of <TEX>$NO_3$</TEX>-N and K obtained with the ion-selective electrodes and standard instruments. However, even though there were strong linear relationships (<TEX>$R^2$</TEX> > 0.94) between the <TEX>$NO_3$</TEX>-N and K concentrations determined by the Gran's plot-based multiple standard addition method and by standard instruments, hydroponic <TEX>$NO_3$</TEX>-N concentrations measured with the ISEs, on average, were about 10% higher than those obtained with the automated analyzer whereas the K ISE predicted about 59% lower K than did the ICP spectrometer, probably due to no compensation for a difference between actual and expected concentrations of standard solutions directly prepared.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.