Abstract

The subject of consideration in the article is a mathematical model for calculating the main parameters of regenerative MGTPs when using bypassing cyclic air past the regenerator to control heat generation for cogeneration MGTPs. It has been established that the use of air bypassing past the regenerator makes it possible to change the amount of heat generated by the cogeneration MGTP over a wide range (up to 75...80%). This makes it possible to meet the needs of local facilities for heat at cyclic or variable heat load, ensuring the stability of the supply of electricity. This model can be used for simplified and preliminary calculations of MGTP.