Abstract

The procedure for conditionally dynamic (quasi-dynamic) hydraulic and thermal calculation of recirculation lines of compressor stations has been developed. As an example, the solution to the problem of reconstruction of the linear compressor station of the main gas pipeline is considered. Using the developed methodology, options for upgrading the existing recirculation line in order to increase its throughput are proposed. The gas temperature change in the recirculation line is analyzed due to various factors (heat exchange with soil, throttling) at the starting modes of constant and variable rotations of the compressor rotor. The analysis of the change in the recirculation cycle time and the rate of temperature growth at the compressor inlet per unit time is performed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.