Abstract

The shear connector design should be executed according to the SP 266.1325800.2016. For the different typed of welded connectors are there analytic dependences, which could be used for shear connection strength estimation. The design code also allows to use powder-actuated Z-shape shear connectors. Their bearing capacity should be proved by tests according to the GOST R 58336-2018. Inasmuch the GOST doesn't consist the test estimation approach, the authors offer the method. For the test estimation methods the test results of 15 series specimen had been used. The results were compared with estimation according to the European standard for the verification.