Abstract

Increase in the service life and noise reduction in pumps is an important area in modern pump engineering. An attempt was made to introduce conjugate calculations in verifying correct operation of the mathematical model as the first step and identifying the main oscillation frequencies of the pump housing subsequently. The FSI interface was used in conjugate calculations at the boundary between liquid and solid media. The obtained oscillation signals were analyzed using the Fourier analysis to identify the main parasitic frequencies in the pump. It was expected that the main parasitic frequency would be the blade frequency. As a result of calculations, it became possible to verify correct operation of the mathematical model by applying it to the simplest model of a glass, which behavior could be easily explained. The mathematical model was tested on cantilever and multistage pumps, demonstrated good results and made it possible to establish that blade frequency was the main oscillation frequency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.