ABSTRACT:The radiant floor heating system is traditional heating system in korea. Radiant floor heating is small in vertical temperature difference, air stream and radiant heat distribution is uniform. And radiant floor heating system provide thermal comfort conditions to the a resident. This study was undertaken to evaluate the physiological-subjective responses of the resident’s posture change such as sitting and standing. The experimental investigations were carried out in climate chamber, and subjects were 4 college-age students in good health. The physiological response was skin temperature and subjective response was undertaken survey of TSV and CSV. The results were summarized as follows; The comfortable temperature range of plantar surface was 35.1~38.9℃ and buttock surface was 37.8~39.3℃.Keywords:Radiant floor heating(바닥 복사 난방), Thermal comfort(온열쾌적감), Skin temperature (피부온도), Plantar(발바닥), Buttock(둔부) †Corresponding author Tel.: +82-51-890-1983; fax: +82-51-890-2625 E-mail address: ksh@deu.ac.kr

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.