Abstract
The article is devoted to the analysis of compressibility factor calculation methods in the temperature range from 220 to 250 K. The AGA8-92DC (GOST 30319.2- 96), AGA8 Report Detail (GOST 30319.3-2015), GERG-2004/2008, NX19, GERG-91, ISO 20765-1 (GOST R 8.662-2009), GSSSD MR 118-05 (moderately compressed gas mixtures) and GSSSD MR 113-03 (Wet Oil Gas) methods are experimentally tested. Deviations of experimental data and calculated values of compressibility coefficient determined by the specified methods are shown. It is found out that the deviation of the calculated values of the compressibility factor according to the AGA8-92DC, AGA8 Report 1 Detail, GERG-2004/2008, ISO 20765-1 (GOST R 8.662-2009), GSSSD MR 13-03 methods from the experimental ones does not exceed 0,1 %. This fact confirms the possibility of using these methods in the temperature range from 220 to 250 K. The results obtained in the framework of this study are highly significant for flow metering, and in particular, provide an increase in the accuracy of the procedure for bringing the volume of natural gas to standard conditions at low temperatures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.