Abstract : There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. However, application standard differs from every industry in domestic or international for application on mythology for allocation and demonstration of SIL. Application or asse ssment is not easy since absence on clear criteria or common definition . This research studied not only fundamental concept of SIL required to guarantee safety in accordance with international standards for safety related equipment and system, but different types of met hodologies for SIL allocation. Specifically, SIL allocation for Platform Screen Door system of railway is studied applying methodology of severity of accidents and risk graph among different methodologies for SIL allocation.