Abstract
. In this article the possibility of suppling the kerosene fraction into the live reflux line of the K-2 column of the atmospheric vacuum pipestill units is reviewed. According to the results of mathematical calculations in the Petro-SIM software, the fraction 140-240°С was determined as optimal for supplying into the top live reflux line of the K-2 column of the atmospheric vacuum pipestill unit. This action makes it possible to reduce the load on the condensing system of the K-2 column of the atmospheric vacuum pipestill units; the heat potential of the hotter kerosene flow also increases, both for heating oil and for generating low-pressure steam. The article describes the advantages of the method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.