The dynamical breakdown voltage in a long (80 cm) discharge tube is measured for neon, argon, their mixture, and argon with mercury vapors at a pressure of 80 – 400 Pa in a wide range of anode voltage rise rate (dU/dt ~ 10–4 – 102 kV/ms). Non-monotonous dependence of the breakdown potential on the dU/dt magnitude is found, with the minimum at 0.1 – 10 kV/ms values. The growth of the breakdown voltage at higher dU/dt is caused by existence of the breakdown delay time. The increase in the breakdown potential in a lower voltage rise rate is presumably due to specialty of the breakdown in long tubes and is a result of the deposit of the surface charge on the tube wall. The charge diminishes potential difference between the anode and the wall, so obstructing the initial breakdown between them. The data of additional experiments with the pulses raised to the constant level pedestal confirm the possibility of such explanation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.