Abstract

In this study, Mokpo national maritime university Training ship Centralizes Air Conditioning System was upgraded by installing onboard an Air-cooled Air conditioner. This resulted in the improvement of the performance and operation. This study compared refrigeration performance to former equipment and improving one. And through the actual measurement study about the cabin thermal environment, it will be used as basic data for marine air conditioning design and plan in the future. At same climate condition, when the Centralized Air Conditioning System and an improved air conditioning system operated, cabin temperature was at , humidity was 55~75 % as comfortable condition, Generator load measurement showed a saving of 48KW in the average load and 8 % in the full load factor. This also resulted in a saving of daily fuel oil consumption(FOC) at around 222 [] average. On the other hand, one cadet cabin(Cadet No.21) indicated a higher temperature due to heat transmission of engine room. It found us not to consider installing additional diffuser to reduce the heat transmission.